Conformance

FerroEHR makes a measured claim: it is an openEHR-spec-conformant Clinical Data Repository, and that claim is backed by a test run you can reproduce, not by prose. This chapter explains what conformance means here, how to run the suite — against this server, against another CDR, or against any deployed endpoint you point it at — and how to read the artefacts it produces: the report, the statement, the certificate, and the cross-server comparison matrix.

What is measured

Conformance is checked by the CNF 2.0 reference runner — a data-driven interpreter over a committed, machine-readable catalogue authored from the openEHR Conformance framework itself: protocol-neutral case cores anchored on the official platform test schedule (case ids follow the schedule’s own naming, e.g. I_EHR_SERVICE.create_ehr-main), per-ITS operation bindings mapping every outcome to its OpenAPI-cited wire expectation, closed vocabularies for outcomes/selectors/captures, a provenance-stamped corpus (the official openEHR Robot data sets re-adjudicated to spec-text-only evidence), and a typed ambiguity register — a spec silence is never resolved privately. Every expectation traces to specification text, never to any server’s observed behaviour. The catalogue spans the schedule’s chapters:

ChapterScope
EHR / EHR_STATUSEHR service and status operations
COMPOSITION / CONTRIBUTION / DIRECTORYClinical content, change sets, folder trees
DEFINITIONADL 1.4 + ADL 2 template and stored-query provisioning
QUERYAQL query execution with committed result-set grounds
CONTENTReference-Model and archetype-constraint accept/reject tables
DEMOGRAPHIC / ADMIN / MESSAGINGParty, admin, and messaging services
SF / SEC / PERFSimplified formats, security, performance classes

The run is what turns cases into a claim. Verdicts are computed, never asserted: a pure function rolls per-case outcomes up through the capability→tier matrix from the CNF Profiles book into Core / Standard / Options / SEC-BASIC profile verdicts, honouring the party statement’s declared capabilities and option selections. A case whose wire does not exist on the technology profile, or whose ground a shared server cannot establish, is recorded as not applicable with a machine-readable citation rather than silently omitted.

Note

The runner, catalogue, and verdict pipeline live in tools/cnf-runner; the published JSON Schemas for every artifact family are committed under tools/cnf-runner/schemas/. The instrument is built from the currently pinned specifications (Reference Model 1.2.0, AQL 1.1.0, Terminology 3.1.0, ITS-REST 1.1.0). The upstream Robot suites are reference material; their official data fixtures enter the corpus only as provenance-stamped re-adjudications.

The current result

The whole conformance story in one picture — every capability of the claims matrix, grouped by profile tier, colored AND glyph-marked by the evidence its cases produced (both charts are generated from the committed runner artifacts and regenerate-and-diff guarded in CI; no number on them is hand-typed):

The same run broken down two levels deep: a header per schedule chapter with its total, then one bar per band — the surface a case actually exercises (EHR resource, EHR_STATUS, COMPOSITION, …) — with the exact passed, FAILED, errored and cited-N/A counts printed beside every row. Every band the taxonomy declares is drawn, so one with no case for this run shows as an explicit no cases row rather than disappearing, and a hatched segment marks cited-N/A so it reads as neither a pass nor a failure:

The published run against FerroEHR reports:

  • 863 case-by-format executions: 826 passed, 0 failed, 0 inconclusive, 37 not applicable with a machine-readable citation (run of 2026-07-31).
  • Profile verdicts — Core: PASS. Standard: PASS. Options: PASS. Security (SEC-BASIC): PASS.
  • 43/43 capabilities satisfied (passed, or excused by a schedule-registered ambiguity — an unrealizable wire on this technology profile is an explicit scope exclusion, never a silent pass).

Cases that did not execute are not-applicable with a machine-readable citation (an unrealized wire on this technology profile, an undeclared option branch, or a ground a shared server cannot establish) — never silent omissions. Options aggregates optional capabilities under the Profiles book’s “any passes” rule.

Any server can be assessed

The runner is deliberately not tied to FerroEHR. It assesses any openEHR CDR reachable over HTTP and emits the same artefact set for each system under test, into its own directory:

  • FerroEHR (the default) — the composed stack built from the current sources. This is the project’s own gate: a phase can only close on a run with zero drift against the committed baseline.
  • Upstream EHRbase (Java)CONF_SUT=ehrbase-java composes the official ehrbase/ehrbase image (with its companion PostgreSQL) on fresh volumes and runs the same catalogue with upstream’s own committed party set. Its measured artifacts live under docs/conformance/ehrbase-java/ and feed the comparison page.
  • Bring your own endpoint — point the runner at any deployed CDR by URL and credentials, with its own party set (an ixit.json naming the instances and credential environment variables, and a statement.json — the ICS — declaring the capabilities and ambiguity-register options the vendor claims; option branches the ICS does not declare are excused as not-applicable with a citation, ISO/IEC 9646-style test selection). No code or adapter is needed; a target is a configuration entry. The ixit.json may also declare deployment facts no openEHR operation exposes — system_id, the identifier the server stamps into the commit audit and into the version ids it mints; and terminology, the terminology query servers the deployment is wired to, the terminology namespaces each one answers for, and what the deployment does with a bound value set it cannot resolve. Cases that check such a value read the declaration; a party that declares none has those cases recorded not-applicable rather than checked against a guess.

Running the suite yourself

The suite runs against a real, deployed server — the same container image and stack a deployment uses — so the wire under test is always the production artefact, never a re-wired in-process stub. From a checkout with Docker available:

# our server, from the current sources (the default)
bash scripts/conformance.sh

# upstream EHRbase (Java), from the official images
CONF_SUT=ehrbase-java bash scripts/conformance.sh

# any deployed CDR, by URL (credentials via the SUT_* variables the
# ixit references)
CONF_SUT=byo CONF_BASE_URL=https://your-host/ferroehr/rest/openehr/v1 \
  SUT_USER=user SUT_PASS=password bash scripts/conformance.sh

The script brings up the selected stack on fresh volumes (for byo it manages nothing), executes the committed catalogue, computes the verdicts through the pure pipeline, and writes the artefacts to docs/conformance/<sut-name>/ before tearing the stack down.

Useful knobs: a case-id filter as the first argument, CONF_IXIT / CONF_STATEMENT for a custom party set, CONF_NO_COMPOSE to run against an already-deployed stack, and cnf-runner verdicts to recompute the documents from a previous results.json without re-running.

Configuration lanes

Some behaviour only exists in a particular server configuration, and a run against the default configuration cannot reach it. Those get their own lane: a compose overlay plus the matching party artefacts, selected by one environment variable. Each lane is a separate, deliberate run — the default lane stays the published baseline.

# openPGP version signing instead of the default digest (stacks on the
# standard posture)
CONF_SIGNING_MODE=pgp bash scripts/conformance.sh

The SMART resource-server posture is the standard conformance posture for ferroehr — every pipeline run boots the server with smart.enabled, smart.require_smart_scopes and an auth.oidc issuer it trusts (docker/sut-smart.yml), and the runner’s principals present minted Bearer tokens carrying the roles and resource scopes each case needs. The SMART discovery document, the resource-scope grammar, and the fail-closed 403 are executable cases in the same committed record as everything else; a SUT whose ixit declares no smart block (upstream EHRbase) records those cases not-applicable with the citation instead. The tokens are signed by a committed test issuer under tools/cnf-runner/party/smart/ — public test key material for the conformance harness, never usable for anything else.

An external terminology server is part of the standard posture too. An archetype can constrain a coded element to a value set that only an external terminology query server can resolve, so the pipeline composes a real FHIR R4 server beside the CDR (--profile terminology plus docker/sut-terminology.yml), seeded with synthetic test code systems and value sets, and the one committed record covers the terminology-routed surface: AQL TERMINOLOGY() resolved through the routed server, and commit-time validation of a bound value set — accepted for a member code, refused for a non-member. What a deployment does when the value set cannot be resolved at all is not decided by any openEHR text, so it is a declared posture: the primary deployment runs fail-open (the commit is accepted) and the second one runs fail-closed (it is refused), and both branches execute in the same record.

Cases that need a lane are recorded not-applicable with a citation on a party that does not declare it, never failed: the party’s ixit.json is where a deployment declares the posture it runs.

Reading the artefacts

A run writes one machine record and three human-readable documents to docs/conformance/<sut-name>/. Each has a distinct job.

The machine record

results.json is the party results record (its JSON Schema is published at tools/cnf-runner/schemas/results.schema.json): one outcome per case with its rows-driven coverage, failing step and reason where applicable, and the excusing citation for every not-applicable entry, alongside the SUT identity, the runner’s verification-pack status, the technology profile, and the ixit digest. verdicts.json is the computed verdict report. Every other artefact is generated from these two — nothing downstream is hand-edited.

The conformance report

CONFORMANCE_REPORT.md is the honest, scoped record of this run: the system under test, the outcome counts, the per-capability evidence rollup, the machine-computed profile verdicts, and every not-applicable entry with its excusing citation. Read this when you want to know exactly what happened and why any case did not run.

The conformance statement

CONFORMANCE_STATEMENT.md is the concise, generated claim: the supported specification versions, the declared external data formats (JSON and XML), and the profile results. Every line is a pure function of the machine verdicts, so the statement can never claim more than the run proves.

The conformance certificate

CONFORMANCE_CERTIFICATE.md follows the structure of the openEHR conformance certificate template: the system under test, the scope of test, and a per-capability profile report showing which capabilities are required in each profile, what each was verified against, and whether each passed. The Realization column separates capabilities verified over released ITS-REST operations from any verified over routes a product serves of its own design — the latter never gate an openEHR profile tier. Where the certificate carries a measured run, its Workload Coverage table additionally shows which claimed capabilities the hospital-simulation load actually exercised; a capability the simulation does not reach must carry an adjudicated exclusion, printed with its reason, and the runner’s validate gate refuses an artifact tree that leaves such a row undecided. It is emitted for every assessed system — FerroEHR, upstream, or your own — and always identifies itself as a framework assessment with the claim computed from the attached run; it is never an official openEHR certification. This is the document to hand to a procurement or evaluation reviewer who wants the capability-by-capability picture.

The comparison matrix

docs/conformance/COMPARISON.md is the fully generated multi-SUT record: profile verdicts, the capability-by-capability evidence matrix, and failure tables in both directions, derived from the two committed results/verdicts sets (ours and upstream EHRbase’s) by scripts/render-comparison.sh — measured numbers only, no editorial adjustment, both directions always published. The same content renders as the comparison page.

Tip

The conformance badges in the project README are generated from the same run and carry the measured amounts (per-profile capability counts, the overall passed/driven case count). A badge can never show PASS unless the machine verdict does — so a green badge is a claim you can immediately reproduce with scripts/conformance.sh.

What conformance does not cover

The catalogue measures the openEHR platform surface, including the simplified (FLAT/STRUCTURED) formats chapter of the ITS-REST specification. It deliberately does not stand in for a performance benchmark (durations are telemetry only — the benchmark harness owns that claim). A capability whose wire cannot exist on this technology profile (for example ADL 1.4 archetype provisioning, which ITS-REST 1.1.0 defines no endpoint for) is excused through the schedule’s typed ambiguity register and reported as an explicit scope exclusion on the certificate — never a silent pass and never an unavoidable failure.